(Product Code: LOGKACO2) |
| The KeepAlert Logger is designed to measure CO2 levels as
well as temperature and humidity. It can ‘wake up’, take
readings, store them in memory and then go back to sleep.
This conserves battery power. It has a memory of 5,200
readings. The KeepAlert Logger measures up to 30% CO2
level |
| |
For AUD 820
|
| [ Other Products >>> ] |
| |
| |
|
|
| |
Uses
- Cold Chain Management
- Agricultural Production
- Transport
- Shipping
- Monitoring of office environments
- HVAC Systems
- Storage and Warehousing
- Agricultural Research
- Horticulture
|
|
| |
|
|
|
| |
|
|
| |
Features and Benefits
- Automatic recording of CO2, Temperature and Humidity
- Easy to download information
- Reusable
- Robust
- No need for External Probes
- Cleanable
- NATA Certifiable
- Replaceable batteries
- Non-dispersive Infrared measurement
- Portable
- Single Unit
- On off switch
- Uses 4 x AA batteries
|
|
| |
|
|
|
|
| How is it Used? |
- Turn off the KeepAlert Logger
- Set up how often you want the CO2, temperature and humidity recorded with the user-friendly software
- Place the KeepAlert Logger into the area where data is to be logged.
- Turn On
- When required plug the KeepAlert Logger back into the computer and see
exactly what happened, when and for how long
- Save your results for later reference
|
| |
|
|
| |
Specifications
| Minimum CO2 |
0 ppm |
Accuracy |
0.2 % vol |
| Maximum CO2 |
300,000 ppm (1%) |
Resolution |
|
| Minimum Temperature |
-30 oC |
Accuracy |
0.2 oC @ 25 oC |
| Maximum Temperature |
60 oC |
Resolution |
0.2 oC or 0.1 oC |
| Minimum Humidity |
0 % |
Accuracy |
+/- 3 % |
| Maximum Humidity |
100 % |
|
|
| Sample Rate |
1 min to 255 min c c |
Size |
140 mm x 90 mm x 33 mm |
| Housing Material |
Polycarbonate |
Delay Start |
Manual On Off switch |
| Log Storage |
5200 readings |
Guarantee |
01 year |
|
|
| |
|
|
|